Orderable Name SESPF Sesame Seed, IgE, with Reflex to Sesame Seed Component, IgE, Serum


Ordering Guidance


For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.6 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Useful For

Evaluating patients with suspected sesame seed allergy

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
SESPR Sesame Seed Component, IgE, S No No

Testing Algorithm

Testing begins with analysis of total sesame seed IgE. If the sesame seed total IgE result is negative (<0.10 kU/L), testing is complete.

 

If the sesame seed total IgE result is 0.10 kU/L or more, then sesame seed component (Ses i 1) testing will be performed at an additional charge.

Method Name

Fluorescent Enzyme Immunoassay (FEIA)

Specimen Type

Serum

Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  90 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Reference Values

Class

IgE kU/L

Interpretation

0

<0.10

Negative

0/1

0.10-0.34

Borderline/equivocal

1

0.35-0.69

Equivocal

2

0.70-3.49

Positive

3

3.50-17.4

Positive

4

17.5-49.9

Strongly positive

5

50.0-99.9

Strongly positive

6

≥100

Strongly positive

Concentrations of 0.70 kU/L or more (class 2 and above) will flag as abnormally high.

Reference values apply to all ages.

Day(s) Performed

Monday through Friday

Report Available

Same day/1 to 3 days

CPT Code Information

86003