Orderable Name PLA2I Phospholipase A2 Receptor, Immunofluorescence, Serum
Ordering Guidance
This test can be used in a complementary fashion with a quantitative enzyme-linked immunosorbent assay to confirm a positive result, especially if it is a low-level titer. Since the immunofluorescence is more sensitive, it can also be used to detect or follow patients with low level antibodies not detected by ELISA. Â
Specimen Required
Supplies: Sarstedt Aliquot Tube 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial within 2 hours of collection.
Useful For
Distinguishing primary from secondary membranous nephropathy in patients with low levels of anti-phospholipase A2 receptor (PLA2R) antibodies
Screening for anti-PLA2R antibodies
Monitoring patients with membranous nephropathy at very low antibody titers
Method Name
Indirect Immunofluorescence Assay (IFA)
Specimen Type
SerumSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 14 days | ||
Ambient | 8 hours |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Reference Values
Negative
Day(s) Performed
Monday, Wednesday, Friday
Report Available
3 to 7 daysCPT Code Information
86255
Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.