Orderable Name OXYDS Oxycodone and Metabolites, Serum
Ordering Guidance
This test should only be ordered by healthcare professionals to monitor patients who have been prescribed oxycodone and/or oxymorphone.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Red top (Serum gel/SST are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL serum
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Useful For
Monitoring therapeutic efficacy/compliance in serum specimens of patients who are prescribed oxycodone and/or oxymorphone
Detection and quantification of oxycodone, oxymorphone, noroxycodone, and noroxymorphone in serum
Special Instructions
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Specimen Type
Serum RedSpecimen Minimum Volume
Serum: 0.5 mL
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum Red | Refrigerated (preferred) | 14 days |
| Frozen | 28 days | |
| Ambient | 24 hours |
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | OK |
| Gross icterus | OK |
Reference Values
Therapeutic range/Metabolite information (as applicable):
Oxycodone: 10-100 ng/mL
Noroxycodone: Metabolite of oxycodone
Oxymorphone: Metabolite of oxycodone; 1.0-8.0 ng/mL when used as sole therapy
Noroxymorphone: Metabolite of oxymorphone
Cutoff concentrations:
Oxycodone: 1.0 ng/mL
Noroxycodone: 1.0 ng/mL
Oxymorphone: 1.0 ng/mL
Noroxymorphone: 1.0 ng/mL
Day(s) Performed
Wednesday
Report Available
2 to 9 daysCPT Code Information
G0480
80365 (if appropriate for select payers)