Orderable Name CSTCE Cystatin C with Estimated Glomerular Filtration Rate (eGFR), Serum
Additional Codes
CNE Order Code: CSTCE
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions:
1. Serum gel tubes should be centrifuged within 2 hours of collection.
2. Red-top tubes should be centrifuged and serum aliquoted into a plastic vial within 2 hours of collection.
Useful For
Assessing kidney function in patients suspected of having kidney disease
Monitoring treatment response in patients with kidney disease
An index of glomerular filtration rate (GFR), especially in patients where serum creatinine may be misleading (eg, very obese, older adults, or malnourished patients)
Calculation of Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) cystatin C estimated GFR for patients where serum creatinine may be misleading (eg, very obese, older adults, or malnourished patients)
Method Name
Immunoturbidimetric
Specimen Type
SerumSpecimen Minimum Volume
0.25 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 30 days | ||
Ambient | 7 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | OK |
Gross icterus | Reject |
Reference Values
CYSTATIN C:
18-49 years: 0.63-1.03 mg/L
≥50 years: 0.67-1.21 mg/L
0-17 years: Reference values have not been established. Refer to estimated glomerular filtration rate (eGFR).
ESTIMATED GFR:
>60 mL/min/BSA (body surface area)
Adult eGFR: Estimated GFR calculated using CKD-EPI Cystatin C equation.(1)
Pediatric eGFR: Estimated GFR calculated using Schwartz Cystatin C equation.(12)
Day(s) Performed
Report Available
Same day/1 to 3 daysCPT Code Information
82610
Forms
If not ordering electronically, complete, print, and send one of the following forms with the specimen:
-General Test Request (T239)
-Cardiovascular Test Request Form (T724)
-Renal Diagnostics Test Request (T830)